ApplicationFor use in all stationary, underground, or surface mining applications. For use with drills and pumps, and as portable power and temporary power supply cables.StandardsUL2806Structure1. Con

Application
For use in all stationary, underground, or surface mining applications. For use with drills and pumps, and as portable power and temporary power supply cables.

Standards
UL2806

Structure
1. Conductors:Annealed flexible stranded tin copper
2. Separator:Tape separator between conductor and insulation (if necessary)
3. Insulation:Ethylene-propylene rubber (EPR)

1.core   black
2.cores black/white
3.cores black/white/green 
4.cores black/white/green/red
5.cores black/white/green/red/orange
5. Assembly:Power and grounds cores cabled together to form a round core
6. Filler:rubber filled binder tape over core.
7. Jacket:Black heavy duty CPE thermosetting compound.

KEMA KEUR / CE & RoHS

IEC 60502-1

Chemical & Oil resistance: Acceptable

Impact resistance: AG2 Medium severity

Water resistance: AD5 Jets

ENVIRONMENTAL PERFORMANCE

✔Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.
✔Flame non-propagation based on EN 60332-1 and IEC 60332-1
✔Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
✔Low smoke emission according to EN 61034 and IEC 61034: Light transmittance > 80%.
✔LSHF (Low Smoke Halogen Free) based on UNE-EN 60754-1 and IEC 60754-1.

CHEMICAL PERFORMANCE

✔Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.
✔Flame non-propagation based on EN 60332-1 and IEC 60332-1
✔Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

FIRE PERFORMANCE

✔Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.
✔Flame non-propagation based on EN 60332-1 and IEC 60332-1
✔Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
✔Low smoke emission according to EN 61034 and IEC 61034: Light transmittance > 80%.
✔LSHF (Low Smoke Halogen Free) based on UNE-EN 60754-1 and IEC 60754-1.

Technology


1. Conductor
Electrolytic annealed copper conductor, class 5 (flexible), based on EN 60228 and IEC 60228.

2. Insulation
Cross-linked polyethylene (XLPE) according to IEC 60502-1.
The standard identification of insulated conductors according to HD 308 is the following:
1 x Natural
2 x Blue + Brown
3 G Blue + Brown + Yellow/green
3 x Brown + Black + Grey
3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section)
4 G Brown + Black + Grey + Yellow/green
4 x Brown + Black + Grey + Blue
5 G Brown + Black + Grey + Blue + Yellow/green

3. Outer sheath
Low Smoke Halogen Free (LSHF) polyolefin. Black colour.

Other cables with similar properties

Get In Touch

Have questions? We're here to help. Send us a message and we'll respond as soon as possible.

Please select your country.
Please provide your name.
Please select your needs.
Please provide a valid corporate email.
Please provide your company name.
Please provide your corporate website URL.
Please enter your message.